AN227

Testing Premise Telco or Network Cables

 Written by Paul DeWinter for

AEA Technology, Inc.

 

Abstract

Testing telco pairs used to be a simple continuity check to ensure the pairs were connected correctly and with no shorts or opens.  This worked fine for analog phones (aka POTS) and was pretty much OK for modems up to 56K.  However, with the introduction of high speed digital services and increased deployment of IP level networking services including VoIP the pair’s attenuation loss, reflective events from poor connections and insulation integrity demand another level of testing.

General  

Cat 5 & 6 premise cable testers would be excellent for this task as they can also test Cat 3 or POTS cables.  However, with a price tags ranging $4-6K they are truly too expensive for a company to equip its entire installation and maintenance force.  Most Cat 5 & 6 testers will tell there is an attenuation or miswire, but won’t tell you were.

 

The 20/20 TDR from AEA Technology can be used to prove these pairs are correctly installed and up to the job of supporting services like ADSL2+, VDSL and VoIP.  The 20/20 TDR is a “Step” TDR as opposed the more common “Pulse” TDR.  With a step TDR, accurate distance on a twisted pair or coax cable can be obtained AND the impedance (Z) of the pair or cable over it’s entire length is also displayed.  Additionally, there is no “dead zone” on any range setting, no gain or pulse width to adjust and clearer indications of all events, large or small.  The Step TDRs use a continuous wave of pulses to paint a clear picture of the cable’s condition over its entire electrical length.

 

Applacation:

 

Single pair testing

Testing can be done from the premise NID or CATV connection points using either the telco test lead set with Popper clips or by connecting an RJ11, RJ12 or RJ45 connector lead directly into the 20/20 TDR.  A shorting plug is required at the far end of the pair to ensure the open end seen by the TDR is at the wall jack’s pins and not inside the jack or before the jack.  First step is to display the full length of the pair and place the TDR’s cursor at the pair’s end to mark length while it reads an open at the far end jack.  If the premise wiring is a home run from a connection panel to the wall jack (see figure 1), there should be no other events on the pair except the open at the far end.  If this is an older telco loop (see figure 2) there may be other jacks in series that should only show small reflective events at each jack location.  Now place the shorting plug in the far end jack.  If the cable is wired correctly, the TDRs trace will change from an open to a short at the same distance.

 

 Figure 1

 

Figure2 

 

Poor quality patch cord in last 20 ft. 

Poor quality splice or telco loop connection         at an in-line wall jack outlet  

Figure 3  

 

RJ For RJ11 plugs, connect & short only the Blue and Orange pairs for TIA 568 cable or the red/green and yellow/black pairs for USOC

For RJ12 plugs, connect  & short only the Blue, Orange and Green pairs for TIA 568 cable or the red/green, yellow/black and blue/white pairs for USOC  

Multi-pair testing

 

With one pair proven good, switch the 20/20 TDR to the pairs’ differential mode and perform the same steps – look at the difference in the good pair an another pair in the same jacket. The two pairs should be open at the far end, then shorted at the far end.  The results should be the same length.  A flat trace near 0 with minimal deflection at the cable end.  Note the shorting plug needs to be wired per the pair’s wiring scheme with each pair shorted individually and no shorts between pairs.  See the attached table for USOC (old telco), T-568A or T-568B wiring schemes and figure 3 for wiring RJx plugs for testing.

TIA/EIA and USOC Wiring Standards Table

 

Authority

Wire Map Scheme

Jack/Plug

Wiring Color Code

20/20 TDR

 

 

& pins

 

Input Channel

AEA

Coaxial Connector

Coaxial

Alternative Red/Black Lead

COAX

Technology

Red/Black Clips

4 & 5

N/A

RJ45 CH A

Accessories

Green/Black Clips

3 & 6

N/A

RJ45 CH B

 

Red/Blk & Green/Blk Clips

4/5 & 3/6

N/A

RJ45 CH A D B

 

 

 

 

 

TIA/EIA 568A

T-568A Pair 1

4 & 5

Blue/White

RJ45 CH A

 

T-568A Pair 2

3 & 6

White/Orange

RJ45 CH B

 

T-568A Pair 3

1 & 2

White/Green

RJ45 CH C

 

T-568A Pair 4

7 & 8

White/Brown

RJ45 CH D

 

T-568A D Pairs 1 & 2

4/5 & 3/6

Blue/White & White/Orange

RJ45 CH A D B

 

T-568A D Pairs 1 & 3

4/5 & 1/2

Blue/White & White/Green

RJ45 CH A D C

 

T-568A D Pairs 1 & 4

4/5 & 7/8

Blue/White & White/Brown

RJ45 CH A D D

 

T-568A D Pairs 2 & 3

3/6 & 1/2

White/Orange & White/Green

RJ45 CH B D C

 

T-568A D Pairs 2 & 4

3/6 & 7/8

White/Orange & White/Brown

RJ45 CH B D D

 

T-568A D Pairs 3 & 4

1/2 & 7/8

White/Green & White/Brown

RJ45 CH C D D

 

 

 

 

 

 

 

 

 

 

TIA/EIA 568B

T-568B Pair 1

4 & 5

Blue/White

RJ45 CH A

 

T-568B Pair 2

3 & 6

White/Green

RJ45 CH C

 

T-568B Pair 3

1 & 2

White/Orange

RJ45 CH B

 

T-568B Pair 4

7 & 8

White/Brown

RJ45 CH D

 

T-568B D Pairs 1 & 3

4/5 & 3/6

Blue/White & White/Green

RJ45 CH A D B

 

T-568B D Pairs 1 & 2

4/5 & 1/2

Blue/White & White/Orange

RJ45 CH A D C

 

T-568B D Pairs 1 & 4

4/5 & 7/8

Blue/White & White/Brown

RJ45 CH A D D

 

T-568B D Pairs 2 & 3

1/2 & 3/6

White/Orange & White/Green

RJ45 CH B D C

 

T-568B D Pairs 3 & 4

3/6 & 7/8

White/Green & White/Brown

RJ45 CH B D D

 

T-568B D Pairs 2 & 4

1/2 & 7/8

White/Orange & White/Brown

RJ45 CH C D D

 

 

 

 

 

Telcordia

USOC Pair 1

4 & 5

Blue/White (old = red/green)

RJ45 CH A

 

USOC Pair 2

3 & 6

White/Orange (old = black/yellow)

RJ45 CH B

 

USOC Pair 3

2 & 7

White/Green (old = blue/white)

RJ45 CH D

 

USOC Pair 4

1 & 8

White/Brown

RJ45 CH C

 

USOC D Pairs 1 & 2

4/5 & 3/6

Blue/White & White/Orange

RJ45 CH A D B

 

USOC D Pairs 1 & 3

4/5 & 2/7

Blue/White & White/Green

RJ45 CH A D D

 

USOC D Pairs 1 & 4

4/5 & 1/8

Blue/White & White/Brown

RJ45 CH A D C

 

USOC D Pairs 2 & 3

3/6 & 2/7

White/Orange & White/Green

RJ45 CH B D D

 

USOC D Pairs 2 & 4

3/6 & 1/8

White/Orange & White/Brown

RJ45 CH B D C

 

USOC D Pairs 3 & 4

2/7 & 1/8

White/Green & White/Brown

RJ45 CH C D D

 

 

 

 

 

      

Testing Tips

 

  1. First establish the type of premise wiring scheme, Home Run or Loop .

  2. If testing a Home Run network, tone out the cables and mark their position from both ends. Mark the distribution box with the room & wall, and mark the room jack plate with the distribution box’s jack number or position.  This can also be done with the shorting plug and the 20/20 TDR by noting which run gets shorted at the moment the shorting plug is inserted.

  3. If testing a loop, measure the full length first then plug in the shorting plug it what you believe is the last jack on the loop.  The distance should remain the same open and shorted.  A large drop in distance indicates you are not on the end jack. Keep trying.

  4. If one or more believed end jacks cannot be located, start at the closest jack to the NID and work toward the end of the loop until the broken connection is located. The broken connection will usually be in the first unseen jack or the previous jack on the exit side.

  5. Once the end jack on the loop is located and all the wires are proven good, move to each jack, in loop order, back towards the NID or TDR connection point.  The shorting plug should show which pairs are connected at each room & wall jack.  If a pair is not connected, you may need to open the wall plate and see if that jack was intentionally unwired or if the pair is broken.

  6. Here are some of the most common failures in premise wiring:

    1. Jack was removed to paint a wall and a wire that is broken in the process goes unnoticed when it is reinstalled

    2. Jack pins and/or connection corrosion due to cats spraying the jack to mark their territory.  Go ahead and laugh, but its real.

    3. Home made patch or extension cables with miswires or the wrong type RJx connector.  These connectors come with different teeth on the pins for solid or stranded cable.

    4. Cable damage due to nails, staples