| Network Analyzers: Bravo MRI |
|
|
 |
The Bravo MRI Analyzer product line is used by Medical Industry engineers, installation specialists, production, and QA teams to test and tune transmit and receive coils in MRI Systems. Bravo MRI Analyzers are available in single and dual port versions. This 100 KHz to 200MHz Analyzer has a reduced power output and coil Q calculations. |
The Bravo MRI analyzers are handheld test instruments used by R&D engineers, field service engineers, installation specialists, production, and quality assurance teams to calibrate/tune MRI transmit and receive coils. They provide accurate measurements of impedance, resistance, phase angle, X, Q, return loss, and SWR. The Bravo MRI is a true Vector Impedance analyzer that accurately measures circuit impedances from 2 to 2000 Ohms. The Bravo MRI is capable of simultaneously plotting any two measurements while displaying both plot's respective Y axis scales. Circuit Q is calculated using either serial or parallel resonances. The Bravo MRI's portability and ability to be used in close proximity of the magnetic field make it the ideal test instrument for installing and servicing MRI systems. There is a Cable Nulling capability to eliminate the effects of connecting cables.
AEA Technology offers several configurations of the Bravo MRI product to satisfy your specific requirements. The Bravo MRI covers up to 70 MHz while the MRI EX unit extends the frequency range to 200 MHz. The MRI II adds S21 parameters and is the perfect tool for measuring isolation between coils. The PC Vision Software application provides the user with the capability of remotely operating the Bravo MRI through a serial port connection while viewing Real-Time results on a P.C. The software makes the capture, storage, and printing of documentation and reports easy. The Bravo MRI will save time, reduce capital expenditures, and improve on other costs that are typically associated with the development, production, installation, and servicing of MRI systems. |
|
| FEATURES |
 |
Windows™ 95/98/ME/XP/2000 compatible PC Vision software included. |
 |
Signal Generator Mode - CW signal generator. |
 |
Simultaneously view two separate plots with different scales |
 |
Nonvolatile memories for both Plot Storage and Setup data. |
 |
Lightweight and portable. |
 |
Measure Parallel or Series Resistance & Reactance. |
 |
Large numeric display of center frequency graph values and Q of the left graph. |
 |
EL Backlit SuperTwist display for better contrast and viewing angles. |
 |
Easy transfer of stored memory data to software. |
 |
Cable/Fixture Nulling for both S11 and S21 modes. |
 |
Automatic Calibration and Self-test. |
 |
Auditory cues for non-visual tuning. |
|
| SPECIFICATION |
|
| Range: |
100KHz to 70MHz (0.1-1.5T) & 100KHz to 200 MHz ( 0.1 - 3T) |
| Display Resolutions: |
< 0.02% of center Frequency |
| Measurement speed: |
~2 sweeps / second |
| Frequency display width: |
0 to 12.8 MHz/80 data points/Large readouts./0 to 16 MHz/100 data points/small readouts. |
| Impedance Range: |
2 to 2000 Ohms |
| Impedance plotting scales: |
0 to 100 Ohms Minimum / 0 to 2000 Ohms Maximum |
| Phase angle plotting scales: |
+/- 15 to +/- 180 Degrees |
| Harmonic and spurious: |
>30 dB below fundamental |
| Output power: |
~ -15 dBm@ 50 ohms |
| Serial interface speeds: |
4800 to 57.6K bps |
| Power requirements: |
10-18 VDC at 400 mA. minimum |
| Antenna connector: |
BNC for Bravo MRI &`N`Connector for all others |
| Size: |
8.5 inch x 4.3 inch x 2.25 inch |
| Weight: |
20 oz. |
| Memory: |
16 presets, 8 presets and plots |
| Display: |
SuperTwist backlit LCD 64 x 128 |
| Communications: |
Serial Port |
| Internal Power: |
8 AA Alkaline, NiMH or NiCd batteries |
| External Power: |
90-240 VAC, 50-60Hz wall adapter (included) |
|
| BENEFITS |
 |
Reduces Service Wait Time. |
 |
Reduces Capitol expenditures. |
 |
Improves Reliability. |
 |
Improves Quality. |
 |
Saves Time. |
|
| INCLUDES |
 |
Soft Belt Case: 5001-1002 |
 |
Bravo PC Vision Software : 6014-1220 |
 |
Calibration Load Set, N male : 6015-1301 |
 |
Serial Cable, DB9-to-audio jack, 6ft(2m) : 0070-1201 |
 |
AC adaptor, 90-240 VAC, 50-60Hz : 5001-0202 |
|
|
|
| PRODUCT OPTIONS |
 |
Soft Carrying Case: 6015-1002 |
 |
NiMH Batteries (8 AA) & Charger Kit: 0010-0020 |
 |
Hard Carrying Case: 6015-1003 |
 |
DC Vehicle Adapter: 5001-0250 |
 |
Certificate of Calibration: 6000-0402 |
 |
DC Extender Cable, 20 ft (6m): 0070-1200 |
 |
Calibration Load Set, N female: 6015-1302 |
 |
Calibration Load Set, BNC male: 6015-1303 |
 |
Adapter, N-to-TNC: 0070-1134 |
 |
Adapters, N-to-SMA & Calibration Kit: 6025-0260 |
 |
Adapter, N-to-SO-239: 0070-1195 |
 |
Adapter, N-to-BNC: 0070-1190 |
|
|
|
|
|
|
|
|